<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Measuring Environmental Contamination in Critical Care Using Dilute Hydrogen Peroxide (DHP) Technology: An Observational Cross-Over Study

Loading...
Thumbnail Image
Unable to use the file because of accessibility barriers? Send us feedback

Publication Date

2020-03-01

Publisher

Original

Rights

Due to copyright restrictions this article is unavailable for download.

Version

Published Version

Review Status

Peer Reviewed

Field of Education

Field of Research

Degree

Department

Faculty

Supervisor

Awarding Institution

Degree

Department

Faculty

Supervisor

Awarding Institution

Abstract

Background

The environment has an important role in the transmission of healthcare associated infections. This has encouraged interest in novel methods to improve hygiene in hospitals. One such technology is the use of hydrogen peroxide to decontaminate rooms and equipment; there are, however, few studies that have investigated the effect of continuous dilute hydrogen peroxide (DHP) in the clinical environment. The aim of this study was to examine the use of dilute hydrogen peroxide (DHP) in a critical care unit and measure the microbiological impact on surface contamination.

Methods

We conducted a prospective observational cross-over study in a ten-bed critical care unit in one rural Australian hospital. Selected high-touch sites were screened using dipslides across three study phases: baseline; continuous DHP; and no DHP (control). Quantitative aerobic colony counts (ACC) were assessed against a benchmark standard of ACC >2.5 cfu/cm2 to indicate hygiene failure.

Results

There were low levels of microbial contamination in the unit for baseline; DHP; and no DHP phases: 2.2% (95% CI 0.7–5.4%) vs 7.7% (95% CI 4.3–13.0%) vs 6% (95% CI 3.2–10.4%) hygiene failures, respectively. Significant reduction in ACCs did not occur when the DHP was operating compared with baseline and control phases.

Conclusion

Further work is needed to determine whether continuous DHP technology has a role in decontamination for healthcare settings.

Description

Research Statement

Citation

Oon, A., Reading, E., Ferguson, J. K., Dancer, S. J., & Mitchell, B. G. (2020). Measuring environmental contamination in critical care using dilute hydrogen peroxide (DHP) technology: An observational cross-over study. Infection, Disease and Health, 25(2), 107-112. doi: 10.1016/j.idh.2019.12.005

Source Title

Infection, Disease and Health

Series

International Standard Serial Number

2468-0451

International Standard Book Number

Avondale University acknowledges our Sovereign God as Creator and Provider of all things. We respectfully acknowledge the Awabakal and Darramuragal people as the traditional custodians of the lands on which we live, work, study and worship across our Lake Macquarie and Sydney campuses. We pay our respects to Elders past, present and emerging, and extend that respect to all First Nations People.

Aboriginal Peoples are advised the Library Collection contains images, voices and names of deceased people in physical and online resources. The Library recognises the significance of the traditional cultural knowledges contained within its Collection. The Library acknowledge some materials contain language that may not reflect current attitudes, was published without consent or recognition, or, is offensive. These materials reflect the views of the authors and/or the period in which they were produced and do not represent the views of the Library.

Avondale University is a member of the worldwide Seventh-day Adventist system of universities and colleges.

CRICOS Provider No.: 02731D. RTO: 91191. TEQSA: PRV12015. ABN: 53 108 186 401.

© Avondale University Ltd 2026