<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Reducing Urinary Catheter Use Using an Electronic Reminder System in Hospitalized Patients: A Randomized Stepped-Wedge Trial

Loading...
Thumbnail Image
Unable to use the file because of accessibility barriers? Send us feedback

Publication Date

2019-04-01

Publisher

Original

Rights

Used by permission: the author(s).

At the time of writing Philip Russo was affiliated with Monash University

http://creativecommons.org/licenses/by/4.0/

Version

Published Version

Review Status

Peer Reviewed

Field of Education

Field of Research

Degree

Department

Faculty

Supervisor

Awarding Institution

Degree

Department

Faculty

Supervisor

Awarding Institution

Abstract

Objective: To determine the effectiveness and ease of use of an electronic reminder device in reducing urinary catheterization duration.

Design: A randomized controlled trial with a cross-sectional anonymous online survey and focus group.

Setting: Ten wards in an Australian hospital.

Participants: All hospitalized patients with a urinary catheter.

Intervention: An electronic reminder system, the CATH TAG, applied to urinary catheter bags to prompt removal of urinary catheters.

Outcomes: Catheterization duration and perceptions of nurses about the ease of use.

Methods: A Cox proportional hazards model was used to assess the rate of removal of catheters. A phenomenological approach underpinned data collection and analysis methods associated with the focus group.

Results: In total, 1,167 patients with a urinary catheter were included. The mean durations in control and intervention phases were 5.51 days (95% confidence interval [CI], 4.9–6.2) and 5.08 days (95% CI, 4.6–5.6), respectively. For patients who had a CATH TAG applied, the hazard ratio (HR) was 1.02 (95% CI, 0.91–1.14; P = .75). A subgroup analysis excluded patients in an intensive care unit (ICU), and the use of the CATH TAG was associated with a 23% decrease in the mean, from 5.00 days (95% CI, 4.44–5.56) to 3.84 days (95% CI, 3.47–4.21). Overall, 82 nurses completed a survey and 5 nurses participated in a focus group. Responses regarding the device were largely positive, and benefits for patient care were identified.

Conclusion: The CATH TAG did not reduce the duration of catheterization, but potential benefits in patients outside the ICU were identified. Electronic reminders may be useful to aid prompt removal of urinary catheters in the non-ICU hospital setting. (Received

Description

Research Statement

Citation

Mitchell, B. G., Northcote, M., Cheng, A. C., Fasugba, O., Russo, P. L., & Rosebrock, H. (2019). Reducing urinary catheter use using an electronic reminder system in hospitalized patients: A randomized stepped-wedge trial. Infection Control and Hospital Epidemiology, 40(4), 427-431. doi:10.1017/ice.2019.31

Source Title

Infection Control and Hospital Epidemiology

Series

International Standard Serial Number

1559-6834

International Standard Book Number

Avondale University acknowledges our Sovereign God as Creator and Provider of all things. We respectfully acknowledge the Awabakal and Darramuragal people as the traditional custodians of the lands on which we live, work, study and worship across our Lake Macquarie and Sydney campuses. We pay our respects to Elders past, present and emerging, and extend that respect to all First Nations People.

Aboriginal Peoples are advised the Library Collection contains images, voices and names of deceased people in physical and online resources. The Library recognises the significance of the traditional cultural knowledges contained within its Collection. The Library acknowledge some materials contain language that may not reflect current attitudes, was published without consent or recognition, or, is offensive. These materials reflect the views of the authors and/or the period in which they were produced and do not represent the views of the Library.

Avondale University is a member of the worldwide Seventh-day Adventist system of universities and colleges.

CRICOS Provider No.: 02731D. RTO: 91191. TEQSA: PRV12015. ABN: 53 108 186 401.

© Avondale University Ltd 2026