Reducing Urinary Catheter Use Using an Electronic Reminder System in Hospitalized Patients: A Randomized Stepped-Wedge Trial
| avondale-bepress.context-key | 14105142 | |
| avondale-bepress.submission-path | nh_papers/183 | |
| avondale.affiliate | Northcote, Maria; 0000-0002-6375-9669 | |
| avondale.affiliate | Mitchell, Brett; 0000-0003-4220-8291 | |
| avondale.department | Lifestyle Medicine and Health Research Centre | |
| avondale.faculty | Nursing | |
| avondale.reporting.isPeerReviewed | Peer Reviewed | |
| avondale.reporting.version | Published Version | |
| dc.contributor.author | Rosebrock, Hannah | |
| dc.contributor.author | Russo, Philip | |
| dc.contributor.author | Fasugba, Oyebola | |
| dc.contributor.author | Cheng, Allen C. | |
| dc.contributor.author | Northcote, Maria T. | |
| dc.contributor.author | Mitchell, Brett G. | |
| dc.date.accessioned | 2023-11-01T00:28:29Z | |
| dc.date.available | 2023-11-01T00:28:29Z | |
| dc.date.issued | 2019-04-01 | |
| dc.date.submitted | 2019-03-25T20:08:22Z | |
| dc.description.abstract | <p>Objective: To determine the effectiveness and ease of use of an electronic reminder device in reducing urinary catheterization duration.</p> <p>Design: A randomized controlled trial with a cross-sectional anonymous online survey and focus group.</p> <p>Setting: Ten wards in an Australian hospital.</p> <p>Participants: All hospitalized patients with a urinary catheter.</p> <p>Intervention: An electronic reminder system, the CATH TAG, applied to urinary catheter bags to prompt removal of urinary catheters.</p> <p>Outcomes: Catheterization duration and perceptions of nurses about the ease of use.</p> <p>Methods: A Cox proportional hazards model was used to assess the rate of removal of catheters. A phenomenological approach underpinned data collection and analysis methods associated with the focus group.</p> <p>Results: In total, 1,167 patients with a urinary catheter were included. The mean durations in control and intervention phases were 5.51 days (95% confidence interval [CI], 4.9–6.2) and 5.08 days (95% CI, 4.6–5.6), respectively. For patients who had a CATH TAG applied, the hazard ratio (HR) was 1.02 (95% CI, 0.91–1.14; P = .75). A subgroup analysis excluded patients in an intensive care unit (ICU), and the use of the CATH TAG was associated with a 23% decrease in the mean, from 5.00 days (95% CI, 4.44–5.56) to 3.84 days (95% CI, 3.47–4.21). Overall, 82 nurses completed a survey and 5 nurses participated in a focus group. Responses regarding the device were largely positive, and benefits for patient care were identified.</p> <p>Conclusion: The CATH TAG did not reduce the duration of catheterization, but potential benefits in patients outside the ICU were identified. Electronic reminders may be useful to aid prompt removal of urinary catheters in the non-ICU hospital setting. (Received</p> | |
| dc.identifier.citation | <p>Mitchell, B. G., Northcote, M., Cheng, A. C., Fasugba, O., Russo, P. L., & Rosebrock, H. (2019). Reducing urinary catheter use using an electronic reminder system in hospitalized patients: A randomized stepped-wedge trial. <em>Infection Control and Hospital Epidemiology, 40</em>(4), 427-431. doi:10.1017/ice.2019.31</p> | |
| dc.identifier.doi | https://doi.org/10.1017/ice.2019.31 | |
| dc.identifier.issn | 1559-6834 | |
| dc.identifier.uri | https://research.avondale.edu.au/handle/1897/14105142 | |
| dc.language.iso | en_us | |
| dc.provenance | <p>This article was originally published as:</p> <p>Mitchell, B. G., Northcote, M., Cheng, A. C., Fasugba, O., Russo, P. L., & Rosebrock, H. (2019). Reducing urinary catheter use using an electronic reminder system in hospitalized patients: A randomized stepped-wedge trial. <em>Infection Control and Hospital Epidemiology, 40</em>(4), 427-431. doi: 10.1017/ice.2019.31</p> <p>ISSN: 0899-823X</p> | |
| dc.relation.ispartof | Infection Control and Hospital Epidemiology | |
| dc.rights | <p>Used by permission: the author(s).</p> <p>At the time of writing <em>Philip Russo</em> was affiliated with <em>Monash University</em></p> | |
| dc.rights.license | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | urinary tract infection | |
| dc.subject | urinary catheter | |
| dc.subject | nursing | |
| dc.subject | patient safety | |
| dc.subject | catheter | |
| dc.title | Reducing Urinary Catheter Use Using an Electronic Reminder System in Hospitalized Patients: A Randomized Stepped-Wedge Trial | |
| dc.type | Journal Article |
Files
Original bundle
Loading...
- Name:
- Mitchell__B._2_article_VoR_full_text.pdf
- Size:
- 256.64 KB
- Format:
- Adobe Portable Document Format